Tender For corrigendum : supply of sitc of wall mounted type microprocessor based afd control panel , supplying, installation, testing and commissioning of 20w, 4 feet led batten tube , sf led type solar street light fitting , replacing the faulty capacitor , supplying and fixing of wall fan , supplying and fixing 32 a dp switch fuse unit , sf 16 32a rewirable type fuse unit , s f 16 32a neutral link , wiring for light point ,fan point, exhaust fan point, call bell point group a , wiring for circuit, submain wiring 2 x 1.5 sq.mm 1 x 1.5 sq.mm earth wire , wiring for circuit, submain wiring 2 x 2.5 sq.mm 1 x 2.5 sq.mm earth wire , supplying and fixing following way , single pole and neutral , sheet steel, mcb distribution board 8 way, double door , supply and fixing following 5a to 32a rating , 240v, 415v, 10ka, c curve miniature circuit breaker single pole , supplying and fixing single pole blanking plate , supplying and fixing following rating, double pole, 240 volts, isolator 40 amps , supplying and fixing following rating , double pole single phase and neutral ,240 v ,residual current circuit breaker rccb , supplying and fixing call bell buzzer , supplying and fixing pvc batten angle holder , supply and fixing following modular switch socket 5 6 a switch , supply and fixing following modular switch socket 3 pin 5 6 a socket outlet , supply and fixing following modular switch socket 15 16 amp switch , supply and fixing following modular switch socket 6 pin 15 16 amp socket outlet , supplying and fixing following size modules, gi box 4 module 125mmx75mm , supplying and fixing stepped type electronic fan regulator , providing and fixing 4.00 mm dia copper wire on surface
Tender For bid to ras supply of rrc for addressable fire detection system onboard in ships and yard crafts at nsry karwar -repairs to main control panel , repairs to repeater panel , repairs to control cards , repairs to ionization smoke detector , repairs to multi sensors , repairs to temperature heat detection sensor , repairs to flame detector , repairs to manual call point , repairs to front panel switches , repairs to alarm bells lights hooters , repairs to internal circuit wiring , repairs refurbishment of ups , repairs to cabling from main control panel , reprogramming of the pcbs
Tender For supply, erection, testing and commissioning of 6 kw 3 phase station lighting control panel (63a) with all necessary accessories to complete the work in all respect (2 nos 63a tp contactor, ac supply operation. 1 no. 63a mccb fp, 2 nos. 40a mcb fp, 1no. ,6a sp mcb 02 nos 24 hr.digital display time switch,2 nos.timer 0-60 min range, suitable capacity connector and 1 no. emergency switch, led light indication module for 30% &70% circuit for individual pf at the smr room, necessary wiring as well as push button typeswitch board etc.with suitable capacity copper wire by casing capping etc.) for auto and manual operation. [ warranty period: 30 months after the date of delivery ]
Tender For erection of structures, equipments, earthing, control wiring, yard lighting, control-room & staff quarter electrification etc. for 2x20mva, 66/11kv ankodiya sub-station under nd scheme & opposite end line feeder bays at 66kv koyali substation tal: & dist: vadodara under jambuva construction division of jambuva tr circle.
Tender For supply of spares and accessories for 1 no incomer vcb panel and 2 no outgoing vcb panel along with control wiring and painting at haliyur wtp of kadur-birur town.
Tender For provision, commissioning and testing of existing igbt-based three-phase propulsion (medha) non-ac motor coach for conversion into ac-enabled coach, including mounting and installation of rmpus, supply andfitment of stainless-steel trough assembly below rmpus, air-distribution ducting, and drain-water pipe arrangement to ensure zero leakage into passenger area, as per enclosed specification/annexure. note: rmpus, control panel, and necessary roof-wiring cables will be supplied by railways. prior approval of coach ga drawings for rewiring and modification shall be obtained before commencement of work. [ warranty period: 30 months after the date of delivery ]
Tender For corrigendum : work of 11kv control room shifting from existing cr to new cr building with dismantling/erection of equipment, control wiring, yard lighting, control-room electrification at 66kv kotda (f) s/s under tharad am division under palanpur circle
Tender For corrigendum : tender for work of erection of bay equipment, cr panel, control wiring, earthing etc at 66kv varahi sub-station under deodar division of palanpur circle